Cooling tower packing

Cooling tower packing

15mm Pitch Cooling Tower Media for Flexible Water Contact Applications

15mm Pitch Cooling Tower Media for Flexible Water Contact Applications

Contact: Alano
Address: Shanxi,China
Click:

Product Overview

15mm Pitch Cooling Tower Media for Flexible Water Contact Applications

Our Cooling Tower Media is designed for projects that require a defined 15mm pitch, 5.5° corrugated configuration, and flexible dimensional options. Available in PVC, CPVC, and PP, this fill provides a range of material choices for cooling tower applications where the media specification needs to match the project requirements.

Multiple Material Options for Cooling Tower Media

The product is available in PVC, CPVC, and PP. Different cooling tower projects can have different requirements for fill material, so offering several material options provides greater flexibility when establishing the final media specification.

Material selection can be combined with the required width, length, thickness, pitch, and connection method to create a complete product configuration.

15mm Pitch and 5.5° Surface Configuration

This cooling tower media features a 15mm pitch and a 5.5° angle. The corrugated structure forms the repeated surfaces used within the film-type fill pack, providing a defined physical configuration for the media.

For projects where fill specifications need to be clearly defined, the fixed pitch and angle provide a consistent basis for selecting the required cooling tower media.

Wide Range of Available Dimensions

The available widths include 1220mm, 1320mm, 1520mm, 1600mm, 1620mm, 1700mm, and 1800mm. This range gives customers multiple options when planning the dimensions of a cooling tower fill section.

The length and thickness can be customized, allowing the finished media to be specified according to the dimensions required by the individual project.

Designed for Flexible Fill Pack Configurations

The product supports both glue and hang connection methods. These options allow the media to be assembled according to different fill pack construction requirements.

For replacement projects, the ability to customize dimensions and select the connection method can also help customers specify media that follows the existing fill arrangement.

Water and Material Compatibility Considerations

The material used for cooling tower media forms an important part of the overall fill specification because the media is exposed to circulating water throughout operation. PVC, CPVC, and PP provide different material choices for customers to consider according to their particular water quality, operating conditions, and project requirements.

Rather than treating every cooling tower fill project as identical, customers can select the material together with the required dimensions and fill configuration to establish a more suitable media specification.

Product Specifications

Connection MethodGlue or Hang
Width1220mm, 1320mm, 1520mm, 1600mm, 1620mm, 1700mm, 1800mm
LengthCustomized
ThicknessCustomized
Pitch15mm
MaterialPVC, CPVC, PP
Angle5.5°

Cooling Tower Media Configured to Your Requirements

With PVC, CPVC, and PP material options, multiple widths, customized length and thickness, and two connection methods, this Cooling Tower Media provides a flexible specification for different cooling tower projects. Contact us with your required dimensions and operating conditions to discuss the appropriate media configuration.

User avatar
Arjun Mehta
Industrial Equipment Procurement Manager
We ordered corrugated cooling tower fill for multiple industrial applications. The product quality, packaging, and delivery service were all satisfactory. YS COOLING TOWER PARTS COMPANY understands cu
User avatar
Kenji Sato
Cooling Tower Maintenance Specialist
The cooling tower media supplied by YS COOLING TOWER PARTS COMPANY shows excellent consistency in quality. We appreciate their attention to product details and strict inspection before shipment. The c
User avatar
Luca Romano
HVAC Project Manager
We purchased PVC cooling tower fill from YS COOLING TOWER PARTS COMPANY for an industrial cooling system project. The products arrived on time and were well packed. The performance of the fill media m
User avatar
Michael Anderson
Cooling System Engineer
We have been working with YS COOLING TOWER PARTS COMPANY for our cooling tower maintenance projects. The cooling tower fill quality is stable, the material is durable, and the customized size perfectl
What types of cooling systems can your cooling tower fill media be used for?
Our cooling tower fill material is suitable for various industrial cooling applications, offering stable water distribution and heat exchange performance.We can provide customized fill solutions based
Is the cooling tower fill media suitable for applications requiring fire resistance?
Our PVC cooling tower fill media is manufactured with flame-resistant characteristics to support regular cooling system operation.Material selection and technical details can be reviewed according to
How Long Does It Take To Produce Cooling Tower Fill Media?
Production lead time for cooling tower fill products is arranged according to material options, dimensions, and order details after confirmation.We remain flexible with scheduling discussions to suppo
Can you provide guidance for cooling tower fill replacement or installation?
Our team provides technical recommendations for cooling tower fill media selection, installation methods, and project requirements.We can also help connect customers with qualified service teams or pr
Contact Us for More Information
Cooling Tower Fill with Flexible Material Options for Water-System Compatibility Cooling Tower Media with a Clearly Defined Water-Contact Configuration
Latest Updates

Cooling Tower Fill News

Product information, industry developments, and technical guidance from our cooling tower fill media team.

YS COOLING TOWER PARTS COMPANY
16+Years of Trust
Who We Are

YS COOLING TOWER PARTS COMPANY

YS COOLING TOWER PARTS COMPANY specializes in manufacturing cooling tower fill media, providing engineered heat exchange components for industrial cooling, HVAC, and water treatment applications worldwide.

  • Experienced cooling tower fill production
  • Quality control throughout manufacturing processes
  • Full-cycle support: design, production, customization
  • Global supply service & technical assistance
More About Us
Get In Touch

Cooling Tower Fill Consultation

Share your requirements for cooling tower fill suggestions.

Chat with us on WhatsApp